K3163i Intelligent Protection Relay Test Set

Item número.: 201102
All-in-One design, weight < 17.5kg;
High Power & Accuracy with 6x35A & 4x310V analog outputs;
Complying IEC61850 Sampling Value & GOOSE;
The ever-expanding test library templates;
Optional advance functions like energy meter and transducer calibration
  • K3163i Datasheet en v1.2.1Baixar
MENSAGEM
Descrição
Basic Functions
Universal Relay Test Applications
10 Channels (6x35A & 4x310V) outputs, Each output channels are independent and simultaneous control of magnitude, Phase angle and frequency values, able to inject DC, AC sine wave and up to 60x harmonics.
13 Low-level channels outputs up to 8Vac/10Vdc max.
100/1000Mbit Fiber port for SMV and GOOSE simulations
Variable battery simulator, DC 0-350V, 140Watts max.
Transient play back up to 3KHz
Fully function KRT software testing modules
Graphical test modules and templates for testing of various relays
Quick relay testing facility in Manual mode
Shot/Search/Check, Point & Click testing
RIO/XRIO import & export facility
Switch on to fault test(SOTF)
Power system model for dynamic testing
Online Vector display
Automatic test results assume
Automatic test report creation
Inbuilt GPS and IRIG-B sync end-to-end testing
Anti-clipping detect, Wrong wiring connect alarm and self-protect, overload and overheat protection
3-Years guarantee of free repair and life-long maintenance
Lightweight, <18Kg
Free software upgrade
 

Advance Feature
Complied IEC61850-9-1, IEC61850-9-2, IEC60044-7/8, etc
Transducer calibration (0.02 class)
Energy meter calibration (Mechanical & Electronic meters)

 
Type of relays can be tested:
Items ANSI® No.
IEC61850 numerical IEDs relay & merge unit  
Distance protection relay 21
Synchronising or synchronism-check relays 25
Undervoltage relays 27
Directional Power relays 32
Undercurrent or underpower relays 37
Negative sequence overcurrent relays 46
Overcurrent/ground fault relays 50
Inverse time overcurrent/ground fault relays 51
Power factor relays 55
Overvoltage relays 59
Voltage or current balance relays 60
Directional overcurrent relays 67
Directional ground fault relays 67N
DC overcurrent relays 76
Phase-angle measuring or out-of-step protection relays 78
Automatic reclosing devices 79
Frequency relays 81
Motor overload protection relays 86
Differential protection relays 87
Directional voltage relays 91
Voltage and power directional relays 92
Tripping relays 94
Voltage regulating relays  
Overimpedance relays, Z>  
Underimpedance relays, Z  
Time-delay relays